您好,登录后才能下订单哦!
密码登录
登录注册
点击 登录注册 即表示同意《亿速云用户服务条款》
作者:东方蜘蛛 发表于:2007-07-03 18:25:37
[size=2]硬件环境:2xE3500+2xA5200
软件环境:Solaris 2.6+Sun Cluster2.2+vxvm3.0[/size]
[size=2]一、故障硬盘更换前系统情况:[/size]
# uname -a
SunOS fsmsdb1 5.6 Generic_105181-29 sun4u sparc SUNW,Ultra-Enterprise
# hastat
Getting Information from all the nodes ......
HIGH AVAILABILITY CONFIGURATION AND STATUS
-------------------------------------------
LIST OF NODES CONFIGURED INCLUSTER
fsmsdb1 fsmsdb2
CURRENT MEMBERS OF THE CLUSTER
fsmsdb1 is a cluster member
fsmsdb2 is a cluster member
CONFIGURATION STATE OF THE CLUSTER
Configuration State on fsmsdb1: Stable
Configuration State on fsmsdb2: Stable
UPTIME OF NODES IN THE CLUSTER
uptime of fsmsdb1: 3:29pm up 456 day(s), 13:03, 1 user, load average: 0.62, 0.67, 0.71
uptime of fsmsdb2: 3:28pm up 429 day(s), 22:22, 0 users, load average: 0.01, 0.02, 0.03
LOGICAL HOSTS MASTERED BY THE CLUSTER MEMBERS
Logical Hosts Mastered on fsmsdb1:
fsmsdb
Logical Hosts for which fsmsdb1 is Backup Node:
None
Logical Hosts Mastered on fsmsdb2:
None
Logical Hosts for which fsmsdb2 is Backup Node:
fsmsdb
LOGICAL HOSTS IN MAINTENANCE STATE
None
STATUS OF PRIVATE NETS IN THE CLUSTER
Status of Interconnects on fsmsdb1:
interconnect0: selected
interconnect1: up
Status of private nets on fsmsdb1:
To fsmsdb1 - UP
To fsmsdb2 - UP
Status of Interconnects on fsmsdb2:
interconnect0: selected
interconnect1: up
Status of private nets on fsmsdb2:
To fsmsdb1 - UP
To fsmsdb2 - UP
STATUS OF PUBLIC NETS IN THE CLUSTER
Status of Public Network On fsmsdb1:
bkggrp r_adp status fo_time live_adp
nafo0 hme1:hme3 OK NEVER hme1
Status of Public Network On fsmsdb2:
bkggrp r_adp status fo_time live_adp
nafo0 hme1:hme3 OK NEVER hme1
STATUS OF DATA SERVICES RUNNING IN THE CLUSTER
Status Of Registered Data Services
sybase: On
nfs: Off
Status Of Data Services Running On fsmsdb1
Data Service "sybase":
Database Status on fsmsdb1:
SYBASE_BAK - running;
smsserver - running;
Status Of Data Services Running On fsmsdb2
Data Service "sybase":
Not being managed on this system
RECENT ERROR MESSAGES FROM THE CLUSTER
Recent Error Messages on fsmsdb1
Jun 12 03:02:13 fsmsdb1 unix: NFS server backupserver ok
Jun 15 14:57:59 fsmsdb1 su: 'su root' failed for sybase on /dev/pts/0
Jun 15 14:58:08 fsmsdb1 last message repeated 1 time
Jun 26 02:00:10 fsmsdb1 unix: NFS server backupserver not responding still trying
Jun 26 03:23:39 fsmsdb1 unix: NFS server backupserver ok
Jun 29 11:57:08 fsmsdb1 explorer: Explorer started
Jun 29 12:03:42 fsmsdb1 explorer: Explorer finished
Recent Error Messages on fsmsdb2
Jun 29 12:25:19 fsmsdb2 unix: pseudo-device: lockstat0
Jun 29 12:25:19 fsmsdb2 unix: lockstat0 is /pseudo/lockstat@0
Jun 29 12:26:36 fsmsdb2 unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2200002037c85404,0 (ssd8):^M^M
Jun 29 12:26:36 fsmsdb2 unix: transport rejected (-2)^M^M
Jun 29 12:26:47 fsmsdb2 unix: Vendor 'SEAGATE', product 'ST318304FSUN18G', (unknown capacity)^M
Jun 29 12:28:36 fsmsdb2 last message repeated 8 times
Jun 29 12:29:12 fsmsdb2 explorer: Explorer finished
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c85404,0
1. c0t5d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0
2. c0t10d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0
3. c0t16d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0
4. c0t19d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0
5. c0t26d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0
6. c2t0d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0
7. c2t2d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0
8. c3t65d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0
9. c3t69d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0
10. c3t74d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0
11. c3t80d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0
12. c3t84d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0
13. c3t86d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0
14. c3t90d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0
Specify disk (enter its number): ^D
# iostat -En
c1t6d0 Soft Errors: 0 Hard Errors: 4 Transport Errors: 0
Vendor: TOSHIBA Product: DVD-ROM SD-M1401 Revision: 1007 Serial No: 06/22/00
RPM: 0 Heads: 0 Size: 18446744073.71GB <-8589934591 bytes>
Media Error: 0 Device Not Ready: 3 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c2t2d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08R9T
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c2t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0108L0AG1B
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t10d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L07FTE
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t26d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0044L069NG
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t5d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L080EX
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t19d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0047L07HMS
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t16d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0044L062MP
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 34
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0046L06SNX
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t69d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08BYB
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t84d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08S00
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t90d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08R9D
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t86d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08ETM
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t80d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08EEY
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t74d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0046L06PDB
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c3t65d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0131L0AQ60
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
rmt/0 Soft Errors: 578 Hard Errors: 20 Transport Errors: 0
Vendor: HP Product: C1537A Revision: L706 Serial No: 62
# scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms
Hosts in cluster:
fsmsdb1 fsmsdb2
Private Network Interfaces for
fsmsdb1: hme0 hme2
fsmsdb2: hme0 hme2
Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX //通过format和iostat命令可以看出坏的磁盘刚好是Quorum device磁盘
Logical Host Timeout Value :
Step10 :720
Step11 :720
Logical Host :180
Logical Host : fsmsdb
Node List : fsmsdb1 fsmsdb2
Disk Groups : fsmsdg
Logical Address : fsmsdb
Logical Interface : 1
Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2)
Automatic Switchover : no
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced - - error
c0t5d0s2 sliced dm_c0t5d0 fsmsdg online
c0t10d0s2 sliced dm_c0t10d0 fsmsdg online
c0t16d0s2 sliced dm_c0t16d0 fsmsdg online
c0t19d0s2 sliced dm_c0t19d0 fsmsdg online
c0t26d0s2 sliced - - error
c2t0d0s2 sliced - - error
c2t0d0s7 simple c2t0d0s7 rootdg online
c2t2d0s2 sliced - - error
c3t65d0s2 sliced dm_c3t65d0 fsmsdg online
c3t69d0s2 sliced dm_c3t69d0 fsmsdg online
c3t74d0s2 sliced dm_c3t74d0 fsmsdg online
c3t80d0s2 sliced dm_c3t80d0 fsmsdg online
c3t84d0s2 sliced dm_c3t84d0 fsmsdg online
c3t86d0s2 sliced - - error
c3t90d0s2 sliced - - error
- - dm_c0t0d0 fsmsdg failed was:c0t0d0s2
# vxprint -ht
Disk group: rootdg
DG NAME NCONFIG NLOG MINORS GROUP-ID
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
V NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEX
PL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE
SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODE
SV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODE
dg rootdg default default 0 993346192.1026.fsmsdb1
dm c2t0d0s7 c2t0d0s7 simple 1024 74367 -
Disk group: fsmsdg
DG NAME NCONFIG NLOG MINORS GROUP-ID
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
V NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEX
PL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE
SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODE
SV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODE
dg fsmsdg default default 51000 989998066.1084.fsmsdb1
dm dm_c0t0d0 - - - - NODEVICE
dm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -
dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -
dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -
dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -
dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -
dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -
dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -
dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -
dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -
。。。
v lv_fsmsdb4 gen ENABLED ACTIVE 8388608 SELECT -
pl lv_fsmsdb4-01 lv_fsmsdb4 DISABLED NODEVICE 8392072 CONCAT - RW
sd dm_c0t0d0-06 lv_fsmsdb4-01 dm_c0t0d0 25694536 8392072 0 - RLOC
pl lv_fsmsdb4-02 lv_fsmsdb4 ENABLED ACTIVE 8392072 CONCAT - RW
sd dm_c0t10d0-05 lv_fsmsdb4-02 dm_c0t10d0 33568288 1795272 0 c0t10d0 ENA
sd dm_c0t16d0-05 lv_fsmsdb4-02 dm_c0t16d0 33568288 1795272 1795272 c0t16d0 ENA
sd dm_c3t69d0-05 lv_fsmsdb4-02 dm_c3t69d0 33568288 1795272 3590544 c3t69d0 ENA
sd dm_c0t5d0-07 lv_fsmsdb4-02 dm_c0t5d0 33883992 212040 5385816 c0t5d0 ENA
sd dm_c3t65d0-04 lv_fsmsdb4-02 dm_c3t65d0 16788856 1583232 5597856 c3t65d0 ENA
sd dm_c3t84d0-05 lv_fsmsdb4-02 dm_c3t84d0 33568288 1210984 7181088 c3t84d0 ENA
。。。
# luxadm probe
Found Enclosure(s):
SENA Name:A1C0 Node WWN:50800200000ea490
Logical Path:/dev/es/ses0
Logical Path:/dev/es/ses1
SENA Name:A2C3 Node WWN:50800200000ead38
Logical Path:/dev/es/ses2
Logical Path:/dev/es/ses3
Found Fibre Channel device(s):
Node WWN:2000002037d89d9a Device Type:Disk device
Logical Path:/dev/rdsk/c2t2d0s2
Node WWN:2000002037e493db Device Type:Disk device
Logical Path:/dev/rdsk/c2t0d0s2
# luxadm display 50800200000ea490
SENA
DISK STATUS
SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)
0 On (Bypassed:AB) On (O.K.) 2000002037c3b5a7
1 Not Installed Not Installed
2 Not Installed Not Installed
3 Not Installed On (O.K.) 2000002037c89c7b
4 Not Installed Not Installed
5 On (O.K.) 2000002037d80498 Not Installed
6 Not Installed On (O.K.) 2000002037c54d3d
7 Not Installed Not Installed
8 Not Installed Not Installed
9 Not Installed Not Installed
10 On (O.K.) 2000002037d803f1 On (O.K.) 2000002037c3bf4f
SUBSYSTEM STATUS
FW Revision:1.09 Box ID:0 Node WWN:50800200000ea490 Enclosure Name:A1C0
Power Supplies (0,2 in front, 1 in rear)
0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
A: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
B: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
Disk backplane (0 in front, 1 in rear)
Front Backplane: O.K.(rev.-04)
Temperature sensors (on front backplane)
0:36篊 1:36篊 2:34篊 3:34篊 4:34篊 5:36篊
6:36篊 7:34篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.)
Rear Backplane: O.K.(rev.-04)
Temperature sensors (on rear backplane)
0:36篊 1:36篊 2:36篊 3:36篊 4:36篊 5:34篊
6:36篊 7:34篊 8:34篊 9:34篊 10:34篊 (All temperatures are NORMAL.)
Interconnect assembly
O.K.(rev.-02)
Loop configuration
Loop A is configured as a single loop.
Loop B is configured as a single loop.
Language USA English
# luxadm display 50800200000ead38
SENA
DISK STATUS
SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)
0 Not Installed On (O.K.) 2000002037d83bf4
1 On (O.K.) 2000002037ba26b8 Not Installed
2 Not Installed Not Installed
3 Not Installed Not Installed
4 Not Installed On (O.K.) 2000002037d89c41
5 On (O.K.) 2000002037d84870 Not Installed
6 Not Installed On (O.K.) 2000002037d83b93
7 Not Installed Not Installed
8 Not Installed Not Installed
9 Not Installed Not Installed
10 On (O.K.) 2000002037c8546b On (O.K.) 2000002037d8992a
SUBSYSTEM STATUS
FW Revision:1.09 Box ID:2 Node WWN:50800200000ead38 Enclosure Name:A2C3
Power Supplies (0,2 in front, 1 in rear)
0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
A: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
B: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
Disk backplane (0 in front, 1 in rear)
Front Backplane: O.K.(rev.-04)
Temperature sensors (on front backplane)
0:36篊 1:36篊 2:36篊 3:36篊 4:34篊 5:36篊
6:36篊 7:34篊 8:34篊 9:36篊 10:36篊 (All temperatures are NORMAL.)
Rear Backplane: O.K.(rev.-04)
Temperature sensors (on rear backplane)
0:37篊 1:37篊 2:36篊 3:36篊 4:36篊 5:36篊
6:37篊 7:36篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.)
Interconnect assembly
O.K.(rev.-02)
Loop configuration
Loop A is configured as a single loop.
Loop B is configured as a single loop.
Language USA English
# scconf fsms -q fsmsdb1 fsmsdb2
Checking node status...
Checking host fsmsdb2 ...fsmsdb2 is alive
Getting device information for hosts fsmsdb1 and fsmsdb2
This may take a few seconds to a few minutes...done
Select quorum device for fsmsdb1 and fsmsdb2.
Type the number corresponding to the desired selection.
For example: 1
1) DISK:c0t10d0s2:0050L07FTE
2) DISK:c0t16d0s2:0044L062MP
3) DISK:c0t19d0s2:0047L07HMS
4) DISK:c0t26d0s2:0044L069NG
5) DISK:c0t5d0s2:0050L080EX
6) DISK:c3t65d0s2:0131L0AQ60
7) DISK:c3t69d0s2:0050L08BYB
8) DISK:c3t74d0s2:0046L06PDB
9) DISK:c3t80d0s2:0050L08EEY
10) DISK:c3t84d0s2:0101L08S00
11) DISK:c3t86d0s2:0050L08ETM
12) DISK:c3t90d0s2:0101L08R9D
Quorum device: 1
Disk c0t10d0s2 with serial id 0050L07FTE has been chosen
as the quorum device.
# scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms
Hosts in cluster:
fsmsdb1 fsmsdb2
Private Network Interfaces for
fsmsdb1: hme0 hme2
fsmsdb2: hme0 hme2
Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE
Logical Host Timeout Value :
Step10 :720
Step11 :720
Logical Host :180
Logical Host : fsmsdb
Node List : fsmsdb1 fsmsdb2
Disk Groups : fsmsdg
Logical Address : fsmsdb
Logical Interface : 1
Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2)
Automatic Switchover : no
# rlogin fsmsdb2
Last login: Fri Jun 29 14:18:26 from fsmsdb1
Sun Microsystems Inc. SunOS 5.6 Generic August 1997
# scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms
Hosts in cluster:
fsmsdb1 fsmsdb2
Private Network Interfaces for
fsmsdb1: hme0 hme2
fsmsdb2: hme0 hme2
Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX
Logical Host Timeout Value :
Step10 :720
Step11 :720
Logical Host :180
Logical Host : fsmsdb
Node List : fsmsdb1 fsmsdb2
Disk Groups : fsmsdg
Logical Address : fsmsdb
Logical Interface : 1
Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2)
Automatic Switchover : no
# scconf fsms -q fsmsdb1 fsmsdb2
Checking node status...
Checking host fsmsdb1 ...
fsmsdb1 is alive
Getting device information for hosts fsmsdb1 and fsmsdb2
This may take a few seconds to a few minutes...done
Select quorum device for fsmsdb1 and fsmsdb2.
Type the number corresponding to the desired selection.
For example: 1
1) DISK:c0t10d0s2:0050L07FTE
2) DISK:c0t16d0s2:0044L062MP
3) DISK:c0t19d0s2:0047L07HMS
4) DISK:c0t26d0s2:0044L069NG
5) DISK:c0t5d0s2:0050L080EX
6) DISK:c3t65d0s2:0131L0AQ60
7) DISK:c3t69d0s2:0050L08BYB
8) DISK:c3t74d0s2:0046L06PDB
9) DISK:c3t80d0s2:0050L08EEY
10) DISK:c3t84d0s2:0101L08S00
11) DISK:c3t86d0s2:0050L08ETM
12) DISK:c3t90d0s2:0101L08R9D
Quorum device: 1
Disk c0t10d0s2 with serial id 0050L07FTE has been chosen
as the quorum device.
# scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms
Hosts in cluster:
fsmsdb1 fsmsdb2
Private Network Interfaces for
fsmsdb1: hme0 hme2
fsmsdb2: hme0 hme2
Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE
Logical Host Timeout Value :
Step10 :720
Step11 :720
Logical Host :180
Logical Host : fsmsdb
Node List : fsmsdb1 fsmsdb2
Disk Groups : fsmsdg
Logical Address : fsmsdb
Logical Interface : 1
Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2)
Automatic Switchover : no
# vxdiskadm
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: 4
Remove a disk for replacement
Menu: VolumeManager/Disk/RemoveForReplace
Use this menu operation to remove a physical disk from a disk
group, while retaining the disk name. This changes the state
for the disk name to a "removed" disk. If there are any
initialized disks that are not part of a disk group, you will be
given the option of using one of these disks as a replacement.
Enter disk name [,list,q,?] list
Disk group: rootdg
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
dm c2t0d0s7 c2t0d0s7 simple 1024 74367 -
Disk group: fsmsdg
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
dm dm_c0t0d0 - - - - NODEVICE
dm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -
dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -
dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -
dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -
dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -
dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -
dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -
dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -
dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -
Enter disk name [,list,q,?] dm_c0t0d0
The following volumes will lose mirrors as a result of this
operation:
fsmsdg-stat lv_fsmsdb1 lv_fsmsdb10 lv_fsmsdb11 lv_fsmsdb12 lv_fsmsdb13 lv_fsmsdb14 lv_fsmsdb15 lv_fsmsdb16 lv_fsmsdb2 lv_fsmsdb3 lv_fsmsdb4 lv_fsmsdb5 lv_fsmsdb6 lv_fsmsdb7 lv_fsmsdb8 lv_fsmsdb9 lv_fsmsdbfs lv_mdbs lv_mlogdbs
No data on these volumes will be lost.
The requested operation is to remove disk dm_c0t0d0 from disk group
fsmsdg. The disk name will be kept, along with any volumes using
the disk, allowing replacement of the disk.
Select "Replace a failed or removed disk" from the main menu
when you wish to replace the disk.
Continue with operation? [y,n,q,?] (default: y) y
Removal of disk dm_c0t0d0 completed successfully.
Remove another disk? [y,n,q,?] (default: n) n
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: 11
Disable (offline) a disk device
Menu: VolumeManager/Disk/OfflineDisk
Use this menu operation to disable all access to a disk device
by the Volume Manager. This operation can be applied only to
disks that are not currently in a disk group. Use this operation
if you intend to remove a disk from a system without rebooting.
NOTE: Many systems do not support disks that can be removed from
a system during normal operation. On such systems, the
offline operation is seldom useful.
Select a disk device to disable [,list,q,?] list
DEVICE DISK GROUP STATUS
c0t0d0 - - error
c0t5d0 dm_c0t5d0 fsmsdg online
c0t10d0 dm_c0t10d0 fsmsdg online
c0t16d0 dm_c0t16d0 fsmsdg online
c0t19d0 dm_c0t19d0 fsmsdg online
c0t26d0 - - error
c2t0d0 - - error
c2t0d0 c2t0d0s7 rootdg online
c2t2d0 - - error
c3t65d0 dm_c3t65d0 fsmsdg online
c3t69d0 dm_c3t69d0 fsmsdg online
c3t74d0 dm_c3t74d0 fsmsdg online
c3t80d0 dm_c3t80d0 fsmsdg online
c3t84d0 dm_c3t84d0 fsmsdg online
c3t86d0 - - error
c3t90d0 - - error
Select a disk device to disable [,list,q,?] c0t0d0
Disable another device? [y,n,q,?] (default: n)
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: q
# vxprint -ht
Disk group: rootdg
DG NAME NCONFIG NLOG MINORS GROUP-ID
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
V NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEX
PL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE
SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODE
SV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODE
dg rootdg default default 0 993346192.1026.fsmsdb1
dm c2t0d0s7 c2t0d0s7 simple 1024 74367 -
Disk group: fsmsdg
DG NAME NCONFIG NLOG MINORS GROUP-ID
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
V NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEX
PL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE
SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODE
SV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODE
dg fsmsdg default default 51000 989998066.1084.fsmsdb1
dm dm_c0t0d0 - - - - REMOVED
dm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -
dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -
dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -
dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -
dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -
dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -
dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -
dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -
dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -
。。。
v lv_fsmsdb4 gen ENABLED ACTIVE 8388608 SELECT -
pl lv_fsmsdb4-01 lv_fsmsdb4 DISABLED REMOVED 8392072 CONCAT - RW
sd dm_c0t0d0-06 lv_fsmsdb4-01 dm_c0t0d0 25694536 8392072 0 - RLOC
pl lv_fsmsdb4-02 lv_fsmsdb4 ENABLED ACTIVE 8392072 CONCAT - RW
sd dm_c0t10d0-05 lv_fsmsdb4-02 dm_c0t10d0 33568288 1795272 0 c0t10d0 ENA
sd dm_c0t16d0-05 lv_fsmsdb4-02 dm_c0t16d0 33568288 1795272 1795272 c0t16d0 ENA
sd dm_c3t69d0-05 lv_fsmsdb4-02 dm_c3t69d0 33568288 1795272 3590544 c3t69d0 ENA
sd dm_c0t5d0-07 lv_fsmsdb4-02 dm_c0t5d0 33883992 212040 5385816 c0t5d0 ENA
sd dm_c3t65d0-04 lv_fsmsdb4-02 dm_c3t65d0 16788856 1583232 5597856 c3t65d0 ENA
sd dm_c3t84d0-05 lv_fsmsdb4-02 dm_c3t84d0 33568288 1210984 7181088 c3t84d0 ENA
。。。
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced - - offline
c0t5d0s2 sliced dm_c0t5d0 fsmsdg online
c0t10d0s2 sliced dm_c0t10d0 fsmsdg online
c0t16d0s2 sliced dm_c0t16d0 fsmsdg online
c0t19d0s2 sliced dm_c0t19d0 fsmsdg online
c0t26d0s2 sliced - - error
c2t0d0s2 sliced - - error
c2t0d0s7 simple c2t0d0s7 rootdg online
c2t2d0s2 sliced - - error
c3t65d0s2 sliced dm_c3t65d0 fsmsdg online
c3t69d0s2 sliced dm_c3t69d0 fsmsdg online
c3t74d0s2 sliced dm_c3t74d0 fsmsdg online
c3t80d0s2 sliced dm_c3t80d0 fsmsdg online
c3t84d0s2 sliced dm_c3t84d0 fsmsdg online
c3t86d0s2 sliced - - error
c3t90d0s2 sliced - - error
- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2
# luxadm remove_device -F /dev/rdsk/c0t0d0s2
WARNING!!! Please ensure that no filesystems are mounted on these device(s).
All data on these devices should have been backed up.
Inquiry failed for /devices/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c85404,0:c,raw
# luxadm remove_device -F A1C0,f0
WARNING!!! Please ensure that no filesystems are mounted on these device(s).
All data on these devices should have been backed up.
A1C0,f0 is bypassed (Port:AB).
Could not get device specific information.
# luxadm insert_device A1C0,f0
Notice: A1C0,f0 may already be present.
The list of devices which will be inserted is:
1: Box Name: "A1C0" front slot 0
Please verify the above list of devices and
then enter 'c' orto Continue or 'q' to Quit. [Default: c]:
Hitafter inserting the device(s).
Drive in Box Name "A1C0" front slot 0
Logical Nodes under /dev/dsk and /dev/rdsk :
c0t0d0s0
c0t0d0s1
c0t0d0s2
c0t0d0s3
c0t0d0s4
c0t0d0s5
c0t0d0s6
c0t0d0s7
# luxadm display 50800200000ea490
SENA
DISK STATUS
SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)
0 On (O.K.) 200000203788ecc0 On (O.K.) 2000002037c3b5a7
1 Not Installed Not Installed
2 Not Installed Not Installed
3 Not Installed On (O.K.) 2000002037c89c7b
4 Not Installed Not Installed
5 On (O.K.) 2000002037d80498 Not Installed
6 Not Installed On (Bypassed:AB)
7 Not Installed Not Installed
8 Not Installed Not Installed
9 Not Installed Not Installed
10 On (O.K.) 2000002037d803f1 On (O.K.) 2000002037c3bf4f
SUBSYSTEM STATUS
FW Revision:1.09 Box ID:0 Node WWN:50800200000ea490 Enclosure Name:A1C0
Power Supplies (0,2 in front, 1 in rear)
0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
A: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
B: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Not Installed
Disk backplane (0 in front, 1 in rear)
Front Backplane: O.K.(rev.-04)
Temperature sensors (on front backplane)
0:36篊 1:36篊 2:34篊 3:34篊 4:34篊 5:36篊
6:36篊 7:34篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.)
Rear Backplane: O.K.(rev.-04)
Temperature sensors (on rear backplane)
0:36篊 1:36篊 2:36篊 3:36篊 4:36篊 5:34篊
6:36篊 7:34篊 8:34篊 9:36篊 10:34篊 (All temperatures are NORMAL.)
Interconnect assembly
O.K.(rev.-02)
Loop configuration
Loop A is configured as a single loop.
Loop B is configured as a single loop.
Language USA English
#
# drvconfig;disks
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w210000203788ecc0,0
1. c0t5d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0
2. c0t10d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0
3. c0t16d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0
4. c0t19d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0
5. c0t26d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0
6. c2t0d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0
7. c2t2d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0
8. c3t65d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0
9. c3t69d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0
10. c3t74d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0
11. c3t80d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0
12. c3t84d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0
13. c3t86d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0
14. c3t90d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0
Specify disk (enter its number): ^D
# vxdisksetup -i c0t0d0
vxvm:vxdisk: ERROR: Device c0t0d0s2: online failed:
Device path not valid
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced - - error
c0t5d0s2 sliced dm_c0t5d0 fsmsdg online
c0t10d0s2 sliced dm_c0t10d0 fsmsdg online
c0t16d0s2 sliced dm_c0t16d0 fsmsdg online
c0t19d0s2 sliced dm_c0t19d0 fsmsdg online
c0t26d0s2 sliced - - error
c2t0d0s2 sliced - - error
c2t0d0s7 simple c2t0d0s7 rootdg online
c2t2d0s2 sliced - - error
c3t65d0s2 sliced dm_c3t65d0 fsmsdg online
c3t69d0s2 sliced dm_c3t69d0 fsmsdg online
c3t74d0s2 sliced dm_c3t74d0 fsmsdg online
c3t80d0s2 sliced dm_c3t80d0 fsmsdg online
c3t84d0s2 sliced dm_c3t84d0 fsmsdg online
c3t86d0s2 sliced - - error
c3t90d0s2 sliced - - error
- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2
# vxdiskadm
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: 10
Enable (online) a disk device
Menu: VolumeManager/Disk/OnlineDisk
Use this operation to enable access to a disk that was disabled
with the "Disable (offline) a disk device" operation.
You can also use this operation to re-scan a disk that may have
been changed outside of the Volume Manager. For example, If a
disk is shared between two systems, the Volume Manager running on
the other system may have changed the disk. If so, you can use
this operation to re-scan the disk.
NOTE: Many voldiskadm operations re-scan disks without user
intervention. This will eliminate most needs to online a
disk directly, except when the disk is directly offlined.
Select a disk device to enable [,list,q,?] list
DEVICE DISK GROUP STATUS
c0t0d0 - - error
c0t5d0 dm_c0t5d0 fsmsdg online
c0t10d0 dm_c0t10d0 fsmsdg online
c0t16d0 dm_c0t16d0 fsmsdg online
c0t19d0 dm_c0t19d0 fsmsdg online
c0t26d0 - - error
c2t0d0 - - error
c2t0d0 c2t0d0s7 rootdg online
c2t2d0 - - error
c3t65d0 dm_c3t65d0 fsmsdg online
c3t69d0 dm_c3t69d0 fsmsdg online
c3t74d0 dm_c3t74d0 fsmsdg online
c3t80d0 dm_c3t80d0 fsmsdg online
c3t84d0 dm_c3t84d0 fsmsdg online
c3t86d0 - - error
c3t90d0 - - error
Select a disk device to enable [,list,q,?] c0t0d0
vxvm:vxdisk: ERROR: Device c0t0d0s2: online failed:
Device path not valid
Enable another device? [y,n,q,?] (default: n)
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: 5
Replace a failed or removed disk
Menu: VolumeManager/Disk/ReplaceDisk
Use this menu operation to specify a replacement disk for a disk
that you removed with the "Remove a disk for replacement" menu
operation, or that failed during use. You will be prompted for
a disk name to replace and a disk device to use as a replacement.
You can choose an uninitialized disk, in which case the disk will
be initialized, or you can choose a disk that you have already
initialized using the Add or initialize a disk menu operation.
Select a removed or failed disk [,list,q,?] list
Disk group: rootdg
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
Disk group: fsmsdg
DM NAME DEVICE TYPE PRIVLEN PUBLEN STATE
dm dm_c0t0d0 - - - - REMOVED
Select a removed or failed disk [,list,q,?] dm_c0t0d0
Select disk device to initialize [,list,q,?] list
DEVICE DISK GROUP STATUS
c0t0d0 - - error
c0t5d0 dm_c0t5d0 fsmsdg online
c0t10d0 dm_c0t10d0 fsmsdg online
c0t16d0 dm_c0t16d0 fsmsdg online
c0t19d0 dm_c0t19d0 fsmsdg online
c0t26d0 - - error
c2t0d0 - - error
c2t0d0 c2t0d0s7 rootdg online
c2t2d0 - - error
c3t65d0 dm_c3t65d0 fsmsdg online
c3t69d0 dm_c3t69d0 fsmsdg online
c3t74d0 dm_c3t74d0 fsmsdg online
c3t80d0 dm_c3t80d0 fsmsdg online
c3t84d0 dm_c3t84d0 fsmsdg online
c3t86d0 - - error
c3t90d0 - - error
Select disk device to initialize [,list,q,?] c0t0d0
The following disk device has a valid VTOC, but does not appear to have
been initialized for the Volume Manager. If there is data on the disk
that should NOT be destroyed you should encapsulate the existing disk
partitions as volumes instead of adding the disk as a new disk.
Output format: [Device_Name]
c0t0d0
Encapsulate this device? [y,n,q,?] (default: y)
Select a different device? [y,n,q,?] (default: n)
Replace a different disk? [y,n,q,?] (default: n)
Volume Manager Support Operations
Menu: VolumeManager/Disk
1 Add or initialize one or more disks
2 Encapsulate one or more disks
3 Remove a disk
4 Remove a disk for replacement
5 Replace a failed or removed disk
6 Mirror volumes on a disk
7 Move volumes from a disk
8 Enable access to (import) a disk group
9 Remove access to (deport) a disk group
10 Enable (online) a disk device
11 Disable (offline) a disk device
12 Mark a disk as a spare for a disk group
13 Turn off the spare flag on a disk
list List disk information
? Display help about menu
?? Display help about the menuing system
q Exit from menus
Select an operation to perform: q
Goodbye.
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced - - error
c0t5d0s2 sliced dm_c0t5d0 fsmsdg online
c0t10d0s2 sliced dm_c0t10d0 fsmsdg online
c0t16d0s2 sliced dm_c0t16d0 fsmsdg online
c0t19d0s2 sliced dm_c0t19d0 fsmsdg online
c0t26d0s2 sliced - - error
c2t0d0s2 sliced - - error
c2t0d0s7 simple c2t0d0s7 rootdg online
c2t2d0s2 sliced - - error
c3t65d0s2 sliced dm_c3t65d0 fsmsdg online
c3t69d0s2 sliced dm_c3t69d0 fsmsdg online
c3t74d0s2 sliced dm_c3t74d0 fsmsdg online
c3t80d0s2 sliced dm_c3t80d0 fsmsdg online
c3t84d0s2 sliced dm_c3t84d0 fsmsdg online
c3t86d0s2 sliced - - error
c3t90d0s2 sliced - - error
- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w210000203788ecc0,0
1. c0t5d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0
2. c0t10d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0
3. c0t16d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0
4. c0t19d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0
5. c0t26d0
/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0
6. c2t0d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0
7. c2t2d0
/sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0
8. c3t65d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0
9. c3t69d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0
10. c3t74d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0
11. c3t80d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0
12. c3t84d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0
13. c3t86d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0
14. c3t90d0
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0
Specify disk (enter its number): 0
selecting c0t0d0
[disk formatted]
FORMAT MENU:
disk - select a disk
type - select (define) a disk type
partition - select (define) a partition table
current - describe the current disk
format - format and analyze the disk
repair - repair a defective sector
label - write label to the disk
analyze - surface analysis
defect - defect list management
backup - search for backup labels
verify - read and display labels
save - save new disk/partition definitions
inquiry - show vendor, product and revision
volname - set 8-character volume name
!- execute , then return
quit
format> ver
Primary label contents:
Volume name = < >
ascii name =
pcyl = 7508
ncyl = 7506
acyl = 2
nhead = 19
nsect = 248
免责声明:本站发布的内容(图片、视频和文字)以原创、转载和分享为主,文章观点不代表本网站立场,如果涉及侵权请联系站长邮箱:is@yisu.com进行举报,并提供相关证据,一经查实,将立刻删除涉嫌侵权内容。
相关阅读